WLD-TEC Fuego SCS Pro


WLD-TEC Fuego SCS Pro

The Fuego SCS pro represents a new status among laboratory gas burners.The Fuego SCS pro provides maximum safety and highest convenience for all flame-related applications in the laboratory.

Battery performance

The exclusive Fuego SCS pro provides maximum flexibility. Wireless operation using state-of-the-art rechargeable battery technology guarantees independent operation. Two standard rechargeable batteries allow up to 9 hours of continuous operation. This corresponds to approximately 2000 inoculation loop flaming operations. The Fuego SCS pro has an integrated fast charging function and can be recharged in just 3 hours.

Versatile

The Fuego SCS pro can be operated with the touch-free IR-Sensor, button function or foot pedal*. For all options, different programs exist that have been developed on the basis of practical experience: flexible start-stop functions, continuous application for up to 2 hours or programs for short flame sterilization - exact to the second. When the burner is activated the display shows the remaining burning time. Moreover, the Fuego SCS pro automatically recognizes whether a foot pedal or the Autoloop Pro carrousel for inoculation loops is connected, and displays other functions.

More convenience through the graphic display

The animated and high-contrast graphic display can be easily read under all lighting conditions due to the blue background illumination. The self-explanatory, language-less symbol menu facilitates a rapid selection of all functions. The display is not in your line of sight? Acoustic signals additionally aid the user.

Cooling time reminder for inoculation loops

The precisely adjustable, exact to the second, cooling time reminder aids you in exactly complying with the required cooling period of inoculation loops.

Zero-pressure shut off

The zero-pressure shut-down provides additional safety at the end of work. With it the residual pressure is released from the connection hose and the gas hose's service life is increased.

Temperature regulation for heating media

With the new temperature regulation system and an optional temperature sensor, the laboratory gas burner becomes a temperature-control station.

Gas consumption display

No new cartridge at hand? The new gas consumption display reminds you to have a fresh gas cartridge on hand in a timely manner.

Flexible & individual by selecting user account

The Fuego SCS pro has to 2 user accounts and saves all safety settings, burning times and other parameters for individual and flexible use.

Graphical installatin instructions

Graphic installation and operating instructions at the first switch-on facilitate the initial start-up.

Innovative – The DoubleClick IR-Sensor

This safety function ensures that the burner can only be ignited by activating the DoubleClick IR-Sensor twice. As a result, unintentional ignition or ignition due to dropping or falling objects is virtually impossible, increasing safety considerably.

Top-off-the-Line safety

The Safety Control System SCS© means state-of-the-art safety technology which onstantly analyzes potential hazards and, if necessary, initiates safety measures, such as an interruption of the gas supply. In addition to the ignition and flame control functions and the overheating protection, the new safety package also features continuous burner head control (BHC). BHC unfailingly detects burner head clogging by liquids or solid substances and ensures the correct assembly of the burner head.

Exceptional passive safety features: A residual heat display protects against burns. The automatic unit cut-off function prevents unintentional ignition of the flame when the burner has not been ignited for a longer period.

Modern design

The unique shape is eye-catching. The low casing makes convenient working possible; the streamlined design reduces the disturbance of the air urrent above a clean room workbench to a minimum. The Fuego SCS pro is extremely space-saving. Measurements: 103 x 49 x 130 mm (w x h x d). With the DualKnob for adjusting gas and air flow, the flame can be precisely regulated. The removable burner head can simply be dismantled into its individual components for in-depth cleaning. Clogging is no longer a problem. Spilled liquids flow off through an integrated drain, and solid substances can be effortlessly removed by opening the burner shaft.

Environment-conscious

Excellent energy efficiency in accordance with the most recent standards reduces gas and power consumption. This increases the burning time when gas cartridges are used.

Universal

The Fuego SCS Series can be operated with stationary natural gas and propane / butane gas supplies, cartridge gas or gas cylinders.

Robust

Fabricated entirely of stainless steel, with fireproof controls and a display, protected by heat resistant glass, the Fuego SCS pro can withstand extreme lab conditions.
Fuego SCS pro - Ideal for use in cleanroom workbenches and laboratories.

Technical Details

Technology Microprocessor, illuminated graphic display with acoustic signals as operating aids
6 Programs
IR-Sensor: Start-Stop with timer, 1 sec - 2 h
Auto-Off with timer, 0 sec - 2 h
Foot pedal: Standard (flame during pressed foot pedal)
Start-Stop with timer, 1 sec - 2 h
Button: Start-Stop with timer, 1 sec - 2 h
Temperature regulation: with timer, 1 sec - 2 h
temperature range from +35 °C to +350 °C
Safety features
Safety Control System (SCS) with gas safety cut off: ignition and flame control, temperature monitor burner head clogging and assembly monitor (BHC) automatic unit switch off after 1 - 2h, adjustable tilt sensor (>90°)
Residual heat display: indicated a hot burner head
Zero-Pressure shut-off: end of work procedure to lower the pressure in the supply hose
Comfort functions cooling reminder
gas consumption display for gas cartridges
Gas supply and consumption
Gas connection: 1/4” left with gas filter
Gas types: II2ELL3B/P: natural gas E/LL,18 - 25 mbar
liquid gas, 47,5 - 57,5 mbar
Connected load: 70 g/h liquid gas; 95 l/h natural gas (LL)
Continuous cartridge operation: CV 360 - 40 min,
Express 444 - 50 min,
CG 1750 - 150 min,
C 206 - 170 min,
CP 250 - 210 min,
CV 470 - 370 min
Temperatures
Flame temperature: 1350 °C on liquid gas
1300 °C on natural gas (E)
Temperature threshold level: 1.0 kW liquid gas, 1.0 kW natural gas
Electrical
IR-Sensor detection range: 5 - 50 mm, adjustable
DoubleClick IR-Sensor: time range 0.5 - 2.5 sec (adjust. / disengageable)
Power consumption: 2 VA (stand by max. 0.1 VA)
Switching power supply: 100-240V / 50/60Hz / max. 0.3 A; 9V DC / 1.3A
Level 6 (stand by power consumption max. 0.1W)
Technical Data Battery Operation
Type: NIHM 2.4V (2 x Mignon (AA) rechargeable battery, 1.2V 2600mAh)
Operating time: up to 9 hours of continuous start/stop operation
(up to 2000 inoculation loop annealing operations)
Charging time: 90% / 3 hours
Charging current: 700 mA
Mechanical
Casing and operating controls: stainless steel / glass, UV and solvent resistant
Burner head: removable and decomposable, stainless steel
Cover of burner shaft: Ø 23 mm, with drains
Measurements (w x h x d): 103 x 49 x 130 mm
Weight: 700 g
Licenses
DIN-DVGW Reg.-No.: NG-2211AS0167
CE: EN 61326-1, EN 61010-1, EN 61010-2-010
EU guidelines: 2014/30/EU, 2014/35/EU, 2011/65/EU